Reference Data · New South Wales
Weddin Shire DCP: the dwelling controls, as published.
5 controls for low-density residential — dwelling houses, taken from Weddin Development Control Plan 2014, Chapter 5 – Urban Residential Development. As at 2026-08-29.
NSW has no statewide dwelling setback or site-coverage standard. The LEP sets zone, height and FSR; the numbers that shape a build sit in each council's DCP — here, the 5 that Weddin Shire publishes numerically. Anything its DCP assesses on merit rather than a fixed number is absent from this table: not a zero, and not a permission.
Weddin Shire — published dwelling controls
| Control | Published value | Qualifier |
|---|---|---|
| Front setback | 6 m | Cl 5.7.1 "minimum building line shall be 6 metres" for single detached dwellings in R1 Residential / R5 Village. Performance-based standard, variable on merit (cl 5.2). |
| Secondary street setback | 3 m | — |
| Side setback | 0.9 m | — |
| Minimum boundary setback | 0.9 m | — |
| Rear setback | 0.9 m | — |
Source: Weddin Development Control Plan 2014, Chapter 5 – Urban Residential Development. Clauses: 5.3, 5.5, 5.6, 5.7, 5.8. Open the source DCP.
Scope: R1 dwelling houses. These are the controls for R1, Weddin Shire’s low-density residential zone. Do not apply these figures to a dual occupancy, duplex, secondary dwelling or multi-dwelling housing development — Weddin Development Control Plan 2014, Chapter 5 – Urban Residential Development sets those out separately, and Feasibly has not codified them.
What qualifies these Weddin Shire controls?
- Weddin Shire has no R2 Low Density Residential zone; low-density dwelling houses are governed by DCP Chapter 5 (Urban Residential Development), which applies to R1 Residential and R5 Village zones (cl 5.3).
- Side and rear setbacks share one control (cl 5.8.1): single-storey min 900mm from the side OR rear boundary; hence rear_setback_m, side_setback_m and min_boundary_setback_m all = 0.9m.
- Second-storey setback is 1500mm (1.5m) from side/rear boundary; Class 10 structures (carport/garage) may be 500mm (0.5m) from side/rear boundary (cl 5.8.2, 5.8.4).
- Front control is expressed as a 'minimum building line' of 6m (cl 5.7.1); corner-lot secondary street setback may reduce to 3m (cl 5.7.2).
- Max height 2 storeys and 8.5m; min lot 900m2 with 20m frontage (regular and battle-axe, latter excluding access corridor) — cl 5.5, 5.6.
- No site coverage, landscaped/deep-soil area, or private open space numeric standards are specified for single dwelling houses (Chapter 5). Those exist only in Chapter 6 for multi-dwelling/dual occupancy (e.g. 50m2 POS cl 6.13; 10% landscaping), so all such fields are null here.
- The DCP is performance/merit-based (cl 5.2): numerical standards are guides and Council may vary them where objectives are met.
Wondering how this compares with asking an AI to read the scheme? We wrote that up here.
How reliable is this Weddin Shire DCP data?
These values were machine-extracted from the source DCP and have not been independently re-checked. Treat them as screening grade: good enough to compare councils and to know which questions to ask, not a substitute for reading the clause before you rely on it. This is a different and lower tier of confidence than our Victorian zone schedules, which are read and verified from the source planning scheme by a person. We do not present the two as equivalent.
A council's DCP can be amended at any time and this page reflects the document as at 2026-08-29. Where a control is absent above, the DCP either sets no number or assesses that parameter on merit.
This information is provided for research and preliminary screening only. It does not constitute professional planning, legal or architectural advice. Always verify with Weddin Shire before making decisions.
Weddin Shire planning controls — common questions
Do these Weddin Shire controls apply to a duplex or dual occupancy?
No. The figures on this page are Weddin Shire’s dwelling-house controls. A dual occupancy, duplex, secondary dwelling or multi-dwelling housing development is assessed under different standards, and Weddin Development Control Plan 2014, Chapter 5 – Urban Residential Development states them separately — Feasibly has not codified those, so do not apply the numbers above to one.
Which zone do these Weddin Shire controls apply to?
R1 General Residential — Weddin Shire’s low-density residential zone. Confirmed against the zones the Weddin Shire LEP actually contains. This page presents the low-density residential case; some DCP sections also cover other residential zones, and the source above names the zones it applies to.
What planning controls does Weddin Shire publish for dwellings?
Weddin Shire publishes 5 dwelling controls in Weddin Development Control Plan 2014, Chapter 5 – Urban Residential Development: front setback, secondary street setback, side setback, minimum boundary setback, rear setback. Each value and its clause reference is listed on this page, as at 2026-08-29.
Does NSW have a statewide dwelling setback standard?
No. The Local Environmental Plan sets zone, building height and floor space ratio, but the numbers that shape a dwelling — setbacks, site coverage, landscaped area and private open space — sit in each council’s Development Control Plan. That is why these figures are published per council rather than per state.
How reliable are these Weddin Shire figures?
They are machine-extracted from Weddin Development Control Plan 2014, Chapter 5 – Urban Residential Development and have not been independently re-checked, so treat them as screening grade — good enough to compare councils and to know which questions to ask, not a substitute for reading the clause. This is a lower confidence tier than our Victorian schedules, which a person reads and verifies from the source scheme.
Do these controls apply to every property in Weddin Shire?
No. These are the council-wide published figures for low-density residential — dwelling houses. The zone, any overlays and the consent triggers that actually apply depend on the individual parcel, and a control absent from this page means the DCP either sets no number or assesses that parameter on merit — not that the requirement is zero.
Check a specific address in Weddin Shire
These are the council-wide numbers. Zone, overlays and the consent triggers that actually apply depend on the parcel.
Free, no signup · zone, schedule, overlays and permit triggers for the parcel. Or create a free account for 20 lookups a month.